Connections, Jumpers and LEDs on the SER-DMX:

A) RS-422 Serial Port: This is used to configure the SER-DMX. Although

this connector uses an eight position connector instead of the usual
six, it is still compatible with all of the RS-422 Serial Ports used on
Gilderfluke & Company products. IF you are not using this connec-
tion to bring the DMX-512 into the SER-DMX, then you should use a
six conductor RJ-12 connector when attaching to the serial port.

If you have more than one SER-DMX plugged together side-by-

side, then only one of the cards should have the RS-422 serial data
from your computer attached to it.

The serial data signals from the SER-DMX are brought out on a

eight position RJ-45 (modular telephone style connector). Facing the
end of the cable with the release latch upwards, its pin out is as fol-
lows: