2. Installation
34
[3] Installation of Wiring
There are tapped holes prepared for some purposes such as attaching cables on the bracket of the
actuator. See the external dimensions for the details of the position and diameters. [Refer to 5. External
Dimensions]
٧
Standard Type
ڏ
Top
Tapped
hole
Tapped
hole
Tapped
hole
Bracket (Front)
Bracket (Rear)
Actuator Type
Bracket (Front)
Tapped Hole
Bracket (Rear)
Tapped Hole
Tapping
Diameter
Tightening Torque
[N•m]
SA5C
2×M3, depth 3 4×M3, depth 7
M3
0.83
SA6C
2×M3, depth 4 4×M3, depth 7
M3
0.83
SA7C
2×M3, depth 4 2×M3, depth 8
M3
0.83