7. Connecting with the Controller

29

7. Connecting with the Controller

7.1

Wiring

x

In an application where the cable cannot be affixed, use the actuator in such a way that the cable will only

deflect by its dead weight or give consideration to minimizing the load received by the cable such as using a

self-supporting cable hose or wiring the cable at a large radius.

x

Do not cut and shorten the cable or reconnect the cut end to extend the cable.

x

The standard cable has excellent flexibility, but it is not a robot cable.

x

When storing the cable in a movable wire duct (such as a cable track), use a cable of robot specification.

If you wish to change the cable specification, contact IAI.

[Connection with XSEL-P/Q, SCON and SSEL controllers]

RCS2

IAI’S dedicated connection cable

(Connects the RCA2 and dedicated controller)

r
r

Dedicated controller

XSEL-P/Q

Robot cable

r = 58mm or more (movable)

Standard cable

r = 93mm or more (fixed)
Use a robot cable for the moving section.

SCON

SSEL

Dedicated cables

x

Motor cable CB-RCC-MA*** / Motor cable robot cable CB-RCC-MA***-RB

x

Encoder cable CB-RCS2-PA*** / Encoder cable robot cable CB-X3-PA***

*** indicates the cable length. Up to 30 m can be specified.

Example) 080 = 8 m