8. Notes on Operation

37

8.4

Home return

8.4.1 Home-return Operation

1) As the motor turns, the rod returns to the negative side (actuator frame side) and contacts the mechanical

stopper.

2) The rod reverses and turns by rotating angle D to find encoder Z-phase.

The distance from the mechanical stopper to the position

where Z-phase is detected is as follows.

Lead

2.5 mm

5 mm, 10 mm

Distance

1.7 mm

2 mm

3) The rod turns by rotating angle E from the position where Z-phase was detected, and the attained offset

position (the offset conforms to an applicable parameter value) is set as the home (points zero).

Z-phase detection sensor (fixed side)

Mechanical stopper

Z-phase

Encoder disk (rotating side)

Rotating angle D

Z-phase detection sensor (fixed side)

The offset from the position where Z-phase is

detected to the home is 1.0 mm.

Rotating angle E

Z-phase detection sensor (fixed side)