12. Precautions for Use

12. Precautions for Use

12.1 Setting

the

Acceleration/Deceleration

Set the acceleration/deceleration using the graphs below as a reference.

(1) PTP operation (Set using the SEL language commands ACCS and DCLS.)

(2) CP operation (Set using the SEL Language commands ACC and DCL.)

Maximum speed of CP operation at arm length 300 600 mm/sec
Maximum speed of CP operation at arm length 350 700 mm/sec

Acceler

ation deceleration (%)

Acceler

ation deceleration (%)

Acceler

ation deceleration (G)

IX arm length 300/350

Reference settings for PTP

acceleration/deceleration

IX arm length 300/350

Reference duties for PTP

continuous operation

Maximum

setting range

Reference range for

continuous operation

Reference range of duty for

continuous operation duty

Mass of carrying load (kg)

Duty (%)

Inertial moment (kg-m

2

)

Duty (%) = (Continuous operation /
(Continuous operation + Stopping time)) / 100