5 user wiring and piping – IAI America IX-UNN3515H User Manual

Page 53

Advertising
background image

47

12. Precautions for Use

Shape of Y-terminal

Spacer for user part installation

M4, depth 5

30 N or less

2 N

˜m or less

External force applied to the spacers must not
exceed 30 N in the axial direction or 2 N

˜m in the

rotating direction (for each spacer).

‡7

12.5 User Wiring and Piping

The robot comes with standard cables and tubes that the user can use in a desired wiring/piping configuration.

User connector specifications

Rated voltage

30 V

Permissible current

1.1 A

Conductor size and number of wires

AWG 26 (0.15 mm

2

),

15 wires

Other

Twisted-pair cable
(1 to 24), shielded

Piping specifications

Normal service pressure

0.8 MPa

Dimensions (outer diameter x inner
diameter) and number of tubes

‡4 mm x ‡2.5 mm,
3 pieces

Working medium

Air

ALM (indicator) specifications

Rated voltage

24 VDC

Rated current

12 mA

Illumination color

Red LED

Quick joint
‡4, red

ALM (indicator)

Quick joint
‡4, black

Spacer for user part installation

Quick joint
‡4, white

BK SW
Brake-release switch

User connector

M cable
(outside
robot)

U cable
(outside robot)

PG cable
(outside robot)

BK power cable (outside robot)

Panel Rear

Panel

Air
(

‡4, 3 pcs)

Advertising