IAI America PCON-CFA User Manual

Page 164

Advertising
background image

5. Flow and Commands of Basic MECHA

TROLINK Communication


158



[2] Position/simple direct mode: In this mode, the actuator is operated by specifying position numbers.

You can select whether to specify the target position directly as a value, or use a
value registered in the position data table, by switching a control signal.
For the speed, acceleration/deceleration, positioning band, etc., values
preregistered in the position data table are used. Up to 768 position data points
can be set.
Number of occupied bytes: 8 bytes (4 word)














[3] Half direct mode: In this mode, the actuator is operated by specifying the speed, acceleration/deceleration

and push current, in addition to the target position, directly as values.
Number of occupied bytes: 16 bytes (8 word)













Target position: 100.00 mm

+

Position No. 0

SCON-CA supporting

PROFIBUS-DP

Actuator

Speed

Acceleration Deceleration

Push

: =   $<<
/=   :7 $<<
2 = 8 9 8  $
<<= 8
%88    8   $
*
/= 8 $

2'.'%= :
/1),&32(/

%8

Advertising
This manual is related to the following products: