4. SCON-CA


84

PLC

PLC

Flat cable

Communication
cable

4. PCON-CA/CFA

4.1

Operation Modes and Functions


PCON-CA/CFA controllers supporting PROFIBUS-DP can be operated in a desired operation mode selected
from the following five modes.

Operation Modes and Key Functions

Key function

Remote I/O

mode

Position/simple

direct mode

Half direct mode Full direct mode

Remote I/O

mode 2

Number of occupied

bytes

2 8 16

32

12

Operation by position
data specification

x

{ (*1)

{

{

x

Direct
speed/acceleration
specification

x x

{

{

x

Push-motion
operation

{

{

{

{

{

Current position read

x

{

{

{

{

Current speed read

x

x

{

{

x

Operation by position
number specification

{

{

x x

{

Completed position
number read

{

{

x x

{

Maximum position
table size

512

768

Not used

Not used

512

(*1) The actuator is operated by specifying all position data, other than positions, using position numbers.

[1] Remote I/O mode: In this mode, the actuator is operated by PIOs (24-V I/Os) via PROFIBUS-DP

communication.
Number of occupied bytes: 2 bytes (1 word)
















PCON-CA/CFA not
supporting PROFIBUS-DP

PIO connection

PCON-CA/CFA supporting
PROFIBUS-DP

PROFIBUS-DP