IAI America PCON-CFA User Manual

Page 43

Advertising
background image

3. SCON-CA/CF

A


37


(* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the applicable bit is “0.”)

Signal type

Bit

Symbol

Description

Details

Push-current
limiting value

16-bit data

-

16-bit integer.
Specify the current-limiting value during push-motion
operation.
The specified range is 0 (0%) to 255 (100%).
The actual specifiable range varies with each actuator. (Refer
to the catalog or operation manual for each actuator.)
If a move command is issued by specifying a value exceeding
the maximum push current value, an alarm will occur.

3.6 (2)

b15 BKRL

Forced brake release: The brake is released when the signal
turns ON.

3.4.7 (18)

b14 RMOD

Operation mode: AUTO mode when the signal is OFF, or
MANU mode when the signal is ON.

3.4.7 (19)

b13 DIR

Push direction specification:
When the signal is OFF, the direction of the position obtained
by subtracting the positioning band from the target position is
used.
When the signal is ON, the direction of the position obtained by
adding the positioning band to the target position is used.

3.4.7 (22)

b12 PUSH

Push specification: Positioning operation when the signal is
OFF, or push-motion operation when the signal is ON.

3.4.7 (21)

b11

b10

b9

-

Cannot be used.

-

b8 JOG+

+Jog: The actuator moves in the direction opposite home when
the signal is ON.

3.4.7 (13)

b7 JOG-

-Jog: The actuator moves in the direction of home when the
signal is ON.

3.4.7 (13)

b6 JVEL

Jog speed/inching distance switching: Parameter No. 26, “Jog
speed” and parameter No. 48, “Inching distance” are used
when the signal is OFF, or parameter No. 47, “Jog speed 2”
and parameter No. 49, “Inching distance 2” are used when the
signal is ON.

3.4.7 (14)

b5 JISL

Jog/inching switching: Jog operation when the signal is OFF,
or inching operation when the signal is ON.

3.4.7 (15)

b4

SON

Servo ON command: The servo is ON when the signal is ON.

3.4.7 (5)

b3

RES

Reset: A reset is performed when the signal turns ON.

3.4.7 (4)

b2

STP

Pause: A pause command is issued when the signal turns ON.

3.4.7 (11)

b1 HOME

Home return: A home return command is issued when the
signal turns ON.

3.4.7 (6)

PLC output

Control signal

b0 DSTR

Positioning start command: A move command is issued when
the signal turns ON.

3.4.7 (8)