4. SCON-CA



163



(* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the applicable bit is “0.”)

Signal type

Bit

Symbol

Description

Details

Current position

32-bit data

-

32-bit signed integer indicating the current position.
The unit is 0.01 mm.
(Example) Reading: 000003FF

H

= 1023 (decimal) = 10.23 mm

* If this data is read as a hexadecimal, a negative value is

indicated by a 2’s complement.

4.8 (2)

Force feedback

data

32-bit data

-

32-bit integer.
The unit is 0.01 N.
* If this data is read as a hexadecimal, a negative value is

indicated by a 2’s complement.

4.8 (2)

Current speed

32-bit data

-

32-bit signed integer.
The current speed is indicated.
Positive value: The actuator is moving in the direction opposite
home.
Negative value: The actuator is moving in the direction of
home.
The unit is 0.01 mm/sec.
(Example) Reading: 000003FF

H

= 1023 (decimal) = 10.23

mm/sec
* If this data is read as a hexadecimal value, a negative value

is indicated by a 2’s complement.

4.8 (2)

Alarm code

16-bit data

-

16-bit integer.
If an alarm occurs, an alarm code will be output.
0H is output when no alarm is present.
For details on alarms, refer to the operation manual for the
controller.

4.8 (2)

b15 EMGS

Emergency stop: An emergency stop is being executed when
the signal is ON.

4.6.10 (2)

b14 PWR

Controller ready: The signal turns ON when the controller
becomes ready.

4.6.10 (1)

b13 ZONE2

Zone 2: The signal is ON when the current position is inside
the specified zone.

4.6.10 (12)

b12 ZONE1

Zone 1: The signal is ON when the current position is inside
the specified zone.

4.6.10 (12)

b11

b10

-

Cannot be used.

-

b9 CEND

Load cell calibration complete: This signal turns ON when the
load cell calibration is complete.

4.6.10 (32)

b8 RMDS

Operation mode: The signal is OFF when the current mode
AUTO, or ON when the current mode is MANU.

4.6.10 (19)

b7 BALM

Absolute battery voltage low warning: This signal turns ON
when the voltage drops.

4.6.10 (28)

b6 PUSHS-

Push-motion operation in progress: The signal is ON when the
Push-motion operation in progress.

4.6.10 (25)

b5 PSFL

Missed load during push-motion operation: The signal turns
ON when the actuator missed the load during push-motion
operation.

4.6.10 (23)

b4

SV

Ready: The signal is ON when the servo is ON.

4.6.10 (5)

b3

ALM

Alarm: The signal turns ON when an alarm occurs.

4.6.10 (3)

b2

MOVE

Moving signal: The signal is ON while the actuator is moving.

4.6.10 (9)

b1 HEND

Home return complete: The signal turns ON when the home
return is completed.

4.6.10 (6)

PLC in

put

Status signal

b0 PEND

Positioning complete signal: The signal turns ON when the
positioning is completed.

4.6.10 (10)