IAI America PCON-CFA User Manual

Page 112

Advertising
background image

3. SCON-CA/CF

A

104

3.6.4

Half Direct Value Mode (Number of Occupied Bytes: 16)

This is the operation mode with the target position, positioning band, speed, acceleration/deceleration and

pressing current value set up in the PLC. Set each value in the I/O areas. When the zone function is used,

set it using the parameter Nos. 1, 2, 23 and 24.

The robot cylinder's effective main functions that can be controlled using this mode, are as shown in the

following table.

ROBO cylinder function

{

:Direct control

U

:Indirect control

x:Disable

Remark

Home-return operation

{

Positioning operation

{

Speed and acceleration /

deceleration setting

{

Pitch feed (inching)

{

Pressing operation

{

Speed change during the

movement

{

Operation at different

acceleration and deceleration

x

Pause

{

Zone signal output

U

Parameters must be set.

PIO pattern selection

x

(1) PLC address configuration. (* "n" indicates the first address of each axis.)

Parameter

No.84

PCON-CA/CFA side

input register

PLC side output

address (bytes)

PCON-CA/CFA side

output register

PLC side input

address (bytes)

n, n+1

n, n+1

Target position

n+2, n+3

Current position

n+2, n+3

n+4, n+5

n+4, n+5

Positioning band

n+6, n+7

Command current

n+6, n+7

Speed

n+8, n+9

n+8, n+9

Acceleration/

deceleration

n+10, n+11

Current speed

n+10, n+11

Pressing current-limiting

value

n+12, n+13

Alarm code

n+12, n+13

2

Control signal

n+14, n+15

Status signal

n+14, n+15

(Note) Be careful of using duplicated node addresses.