2.

ACON-C/CG, PCON-C/CG

56

(7) Positioning start (CSTR): Used in the position/simple direct mode PLC output signal

This signal is processed at the startup (ON edge) and the positioning is performed to the target position with

the specified position No. or set using the PLC's target position register.

Whether if the target position with the specified position No. is used or the setting using the PLC's target

position register is used, depends on the Control signal b11: “Position/Simplified Direct Value Change-Over

(PMOD) Signal”.

x

PMOD䋽OFF: Target position data for the specified position No. is used.

x

PMOD䋽ON : Value for the target position set using the PLC's target position register is used.

When this signal is issued in the condition where the home return operation has not performed at all after

the power is applied (HEND signal OFF), the positioning to the target position is performed after the home

return operation is performed automatically.

Turn “OFF” this signal after confirming that the Positioning Completion Signal (PEND) signal has been

turned “OFF”.

(8) Positioning command (DSTR): Used in the half direct mode and full direct mode PLC output signal

This signal is processed at the startup (ON edge) and the positioning to the target position input in the

PLC's target position register is performed. When this signal is issued in the condition where the home

return operation has not performed at all after the power is applied (HEND signal OFF), an alarm is issued

(Operation Cancellation Level).

Turn “OFF” this signal after confirming that the Positioning Completion Signal (PEND) signal has been

turned “OFF”.

(9) Moving signal (MOVE) PLC input signal

This signal is turned ON while the actuator's slider or rod is moving. (Including the pressing or jog operation

after the home return operation)

After the completion of the positioning, home return or pressing operation, or during the pause condition,

this signal is turned “OFF”.