(26) Load output judgment (LOAD) PLC input signal

This signal is available only in the pressing operation.

When this signal is used for pressing-in purpose, it should be know whether if the set load threshold is

reached during the pressing operation.

The load threshold and check range are set by the PLC and the LOAD signal will turn ON when the

command torque (motor current) exceeds the threshold inside the check range.

This signal judges the load output based on the fact that the command torque excesses the threshold for

the specified time period.

This processing procedure is the same as for the pressing judgment. The judgment time period can be

changed freely using the parameter No. 50 “Load Output Judgment Time Period”.

This signal is continued until the next movement command is received.

x

Set the pressing speed using the parameter No. 34 “Pressing Speed”.

When the machine is delivered, it has been individually set depending on the actuator characteristics.

Set an appropriate speed considering the work part material and shape.

x

Set the parameter No. 50 “Load Output Judgment Time Period”.

x

Set the threshold inspected width using the PLC's Zone Boundary + Register or Zone Boundary - Register.

x

Set the threshold using the PLC's Load Current Threshold Register.

x

Set the positioning band using the PLC's Positioning Band Register.

Set it a bit longer from the backmost position considering the mechanical dispersion of the work part.

Refer to the Operation Manual for the controller for more information.

Caution: The actuator continues to push the work part with the pressing current at the stop time decided

with the current-limiting value.

It is not the stop condition, so take the greatest care to deal with it.

Position where this signal is

turned ON when the command

torque exceeds the threshold

within the torque inspected width

Position where the actuator is pushed

against the work and the pressing

completion is judged so the positioning

completion signal is turned “ON”

Speed

Travel

Positioning band (Max. pressing level)

Check range