3 extended idec smartrelay solution, Extended idec smartrelay solution, Applications – IDEC FL1E SmartRelay User Manual
Page 298: 284 idec smartrelay manual
Advertising

Applications
284
IDEC SmartRelay Manual
8.4.3
Extended IDEC SmartRelay solution
Our extended control circuit is to open the gate automatically
when the safety bar is actuated.
x
x
I6
x
Q2
I3
I4
x
I1
Q2
T=
5 s
Q1
T=
5 s
x
Q2
I3
I6
I5
I2
Q1
Q3
T
H
=
T
L
=2 s
Inv=lo
Safety bar
STOP
pushbutton
Gate is open
OPEN pushbutton
CLOSE pushbutton
STOP pushbutton
Safety bar
Gate is closed
Open
Signal
lamp
Close
Advertising