DIGITAL PA COMBINATION SYSTEM

25

PAC-5000

- Set up an ADDRESS

ƒU

Nominate device numbers by combining 1 to 4 of FUNCTION switch.
(Refer to Table below.)

ƒU

When installing several remote MICs, nominating a same number will not matter.

※ Example : When turn on Number 1 and Number 3, to which actual numbers 1 and 4 are added and

then the device number becomes 5.

- Chime setting

ƒU

When turn on FUNCTION switch number 5 on the rear part, it will output

the chime automatically before giving a MIC broadcast.

ƒU

Turn OFF when does not utilize it.

3) Zone selection broadcasting

- When press ZONE button of the zone where to give a broadcasting and then TALK button, it will be

available to give a broadcast. (If the chime selection switch is turned ON, when press TALK button, it will
output a chime automatically.)

- With the MIC volume on the rear part, adjust it for a proper level.
- After giving a broadcast, press TALK button for a long time to terminate the broadcasting.

4) Whole zone broadcasting

- When press ALL button and then TALK button, it will be available to give a broadcast to the whole zones.
- After giving a broadcast, press TALK button for a long time to terminate the broadcasting.

5) Monitoring

With the monitor speaker, it is available to confirm broadcasts in each of the zones.

- When press the monitor button and then the corresponding ZONE button of zone to be monitored, just it

is available to confirm it.
Corresponding broadcast is output through the monitor speaker to a zone in broadcasting. And
monitoring is available for only one ZONE.

- An over inputting may cause to tilt a sound during monitoring so that you should adjust a volume level

properly with the monitor volume on the rear part.

- When press the monitor button one more time, the monitoring is terminated.

Dip Switch

1

2

3

4

5

1 2

4

8

1

ON

OFF

OFF

OFF

2

OFF

ON

OFF

OFF

3

ON

ON

OFF

OFF

4

OFF

OFF

ON

OFF

5

ON

OFF

ON

OFF

6

OFF

ON

ON

OFF

7

ON

ON

ON

OFF

8

OFF

OFF

OFF

ON

ADDRESS

AUTUAL NUMBER

CHIME SEL

(ON/OFF)

PAC5000_E 2008.7.1 5:59 PM 페이지 28