D. ANTENNA

Receives RF signal from wireless remote up to 100 feet.

Binding post allows antenna length insertion for further distances in inclement weather.

It is recommended that the antenna be installed for optimum performance.
E. BACKLIT 30 AMP AMMETER

Meter shows current draw of a selected circuit up to 30 AMPS.
F. 30 AMP FUSE SOCKET

Overload protection.
G. MUTE SWITCH

Flip switch up to mute alert sounds.
H. TROUBLE WARNING INDICATORS

Flashing red LEDs indicate problems that may exist in a selected circuit.

• Overload Indicator

• Open Circuit Indicator

• Reversed (Battery) Polarity Indicator
I. AUTO CYCLE INDICATOR

Illuminates when Auto Cycle is engaged.

Auto Cycle tests all circuits in 5 second intervals in clockwise rotation. (You cannot

access Auto Cycle mode when in Auxiliary or Brake mode). To enter Auto Cycle

mode, press Control Knob once and then a second time to cancel Auto mode.
J. VOLTAGE INDICATOR

Shows supplied battery voltage integrity.

Operating Voltage Range: 12/24 volt DC
K. GROUND INTEGRITY

Large green LED above the Control Knob indicates ground status.

Ground Integrity is automatically verified when power is turned on. If a ground fault is

indicated, attach the supplied 10 ft. ground cord to the chassis of the trailer. If the fault

clears, the problem is in the chassis ground. If the fault continues, the problem is with

the ground return in the plug.
L. CONTROL KNOB

Knob activates all electrical test modes and circuits to be diagnosed.

• Manual Mode

• Auto Cycle Mode

• Warning Sound Bypass

• All Circuits On Mode

• Brake Light Exercise Mode
M. CIRCUIT INDICATORS

The small green LEDs illuminate or blink in testing phase.
N. CHASSIS GROUND OUTLET

Insert supplied ground cable into this socket for trailers using the frame or body for

ground connection instead of ground pin in harness.