Cable testing, Test procedure – IPA Tools 9008-SE Super MUTT Standard Edition User Manual

Page 19

Advertising
background image

19

AUTO SHUTDOWN FEATURE

To preserve battery life, the MUTT

®

enters a Sleep mode if inactive after 20 minutes

with the power On.

• A sound is emitted every 10-20 seconds to inform the operator of the condition.

• Activation of any test mode takes the MUTT

®

out of Sleep mode.

CABLE TESTING

The MUTT

®

has a special cable feature to test 7 round pin cables for continuity. The

cable testing feature can be used to test a tractor’s cable or the supplied MUTT

®

cable.

It is recommended that all cables be tested prior to the MUTT

®

operation.

TEST PROCEDURE

PRIOR TO CABLE TESTING:

To avoid erroneous fault, be certain the 7 pins in each plug are clean and spread to the

proper size.

• Insert each end of the cable into both side connectors on the MUTT

®

.

Be sure to push the cable ends in firmly until they reach the bottom of the connector.

• Turn main power switch to desired power supply.

• Once the power is selected, the green lights around the Control Knob will blink and

disappear one at a time until only the Ground Integrity light remains solid green. Once

the initial check has been performed, poor cable conditions will be shown by a blinking

light for the problem circuit.

• If the cable has an open circuit or continuity problem, the corresponding circuit

flashes repeatedly.

• Further testing can be performed by selecting each circuit individually via the Control

Knob or Remote. When an open circuit is detected, the LED for the circuit will flash

and an audible alert will be heard.

NOTE: Always check the MUTT

®

connector pins at the side of the MUTT

®

for proper ex-

pansion. Over time, the pins may bend in slightly resulting in a poor connection between

the connector and the cable ends. A flat head screwdriver can be used to expand the

pins until the a tight connection is made.