QUICK SET-UP GUIDE

NOTE: The Super MUTT

®

Deluxe is an advanced diagnostic tool designed to

eliminate guesswork and make your job easier. As a general rule, if something is

wrong with your trailer’s electrical system, the MUTT

®

will beep and blink LEDs to

indicate the problem. Air brake testing is straightforward, but should be operated

only AFTER reading the instruction manual. Both Lights and Air Brakes can be

operated by remote control.

1. CHOCK ALL WHEELS BEFORE TESTING BRAKES.
2. INSTALL A FULLY CHARGED GROUP 31, 12 VOLT DC BATTERY
in the battery

compartment of your Super MUTT

®

Deluxe.

3. INSTALL THE ANTENNA (in the included accessories bag) into the MUTT

®

antenna jack (see Fig. 5, page 17).

4. PROGRAM THE REMOTE by holding down the large button of remote while

simultaneously turning the MUTT

®

power On. Release the large button after 2

seconds. The remote control is programmed once the start-up sequence has

finished and the Ground Integrity light on the MUTT

®

remains solid green. The

small button on the remote for Air Brake operation will also be programmed at

this time.

5. CHECK 7 PIN CONNECTORS on both sides of the MUTT

®

before operating

to make sure the pins are spread to the proper width and greased. This ensures

a solid connection.

6. CONDITION 7 PIN CONNECTORS: Use dielectric grease on all connections to

avoid corrosion. If a bad connection exists at the terminal junction, you may get

an erroneous reading or the MUTT

®

will not work properly. Make sure that you

have a solid connection in the 7 way socket (perform cable test).

7. CONNECT THE OUTPUT side of the 7 pin cable to the trailer being tested. Connect

shop air into the clean air source. Optimum test pressure is 100psi (do not exceed

120 psi). Connect the red air hose to the Emergency Side (left) Air Out connection

on the front of the MUTT

®

. Then connect the blue air hose to the Service Side Air

Out connection. Finally connect each of the appropriate glad hand connectors to

the corresponding trailer connection.

8. Optimum testing pressure is 100 PSI.

Advertising