KB Electronics Installs on end of KBVF User Manual

Page 14

Advertising
background image

TABLE 1 – GENERAL PERFORMANCE SPECIFICATIONS

II.

INSTALLATION INSTRUCTIONS

See figure 2, SIVF Connection Diagram, on page 5.

WARNING: HIGH VOLTAGE IS
PRESENT WHILE LEDs ARE ILLUMINATED.

Before wiring the SIVF to the KBVF, disconnect all power to the KBVF and wait until “PWR”
and “ST” LEDs are no longer illuminated.

A.

Wiring the SIVF to the KBVF – (Note: Do not install the SIVF to the KBVF until wiring
is completed.)

1.

Remove the F-S-R jumper which is installed on CONN2 of the KBVF. Attach the
3-pin connector (with white, black, and red wires) from the SIVF to the KBVF con-
nector marked “CONN2”.

2.

Attach the red wire from the SIVF to the KBVF terminal marked “J3”.

3.

Attach the orange wire from the SIVF to the KBVF terminal marked “P2”.

4

Voltage Following Operation Input Range (V DC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 – 2.5 thru 25
Current Following Operation Input Range (mA DC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 – 20

Potentiometer Operation (K

) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Output Voltage at P2 (V DC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 – 5
MIN Trimpot Range (with 0 Volts Input) (% Full Speed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 – 40
MAX Trimpot Range (with 5 Volts Input) (% Full Speed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 – 110
FWD and REV Input Switch Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dry Contact or Open Collector
Linearity (%) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5
Thermal Drift (mV/ ˚C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.0

Electromagnetic Compatibility (V/m at 80-1000M Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Note: If the KBVF contains a finger safe cover,

(KB P/N 9473) see
Addendum I on page 15.