– ADDENDUM I –

Instructions to Modify the Optional Finger-Safe Cover (KB P/N 9473).

If using the optional finger-safe cover on the KBVF, it needs to be modified to install the
KBVF.

WARNING: HIGH VOLTAGE IS PRESENT WHILE LEDs ARE ILLUMINATED.

Before removing the finger safe cover, or wiring the KBVF, disconnect all power to the
KBVF and wait until “PWR” and “ST” LEDs are no longer illuminated.

Note: If a finger-safe cover is already installed on the KBVF, remove it by lifting up on the
four (4) retaining clips (see figure 11, Finger-Safe Cover, on page 16).

Instructions to modify the finger-safe cover:

1.

Cut off the end section with three (3) tabs of the finger-safe cover at nine (9) places,
as shown in figure 11, Finger-Safe Cover.

2.

Before installing the finger-safe cover onto the KBVF, connect orange wire, red wire
and 3-pin connector to KBVF.

3.

Install SIVF onto KBVF before installing the finger-safe cover (see section II, on
page 4).

4.

Install the finger safe cover onto the KBVF using the four (4) retaining clips.

15