KB Electronics KBWS-25D User Manual

Page 11

Advertising
background image

11

II.

PLUG-IN HORSEPOWER RESISTOR®
A Plug-In Horsepower Resistor® (PHR) must be
installed for the KBWS to operate. Select a Plug-
In Horsepower Resistor® to match the motor
characteristics to the control. See Figure 3 and
Table 3 on page 12. The PHR plugs into the two
female terminals that are provided on the KBWS.
Plug-In Horsepower Resistors® are supplied
separately by your distributor.

TABLE 2 – GENERAL PERFORMANCE SPECIFICATIONS

FIGURE 3 – PLUG-IN

HORSEPOWER RESISTOR®

CAUTION: Be
sure Plug-In
Horsepower
Resistor® is
inserted com-
pletely into
mating sockets.

Parameter

Specification

Factory Setting

AC Line Voltage Regulation (% Base Speed)

0.5

Load Regulation (% Base Speed)

± 1

Armature Voltage Range at 115 Volt AC Line Input (Volts DC)

0 – 130

90

Armature Voltage Range at 208/230 Volt AC Line Input (Volts DC)

0 – 130, 0 – 220

180

Maximum Load Capacity (% for 2 Minutes)

150

Switching Frequency at Motor (kHz)

>16

Signal Following Input Voltage Range (Volts DC)

0 – 5

Maximum Speed Trimpot (MAX) Range (% Base Speed)

70 – 100

100

Minimum Speed Trimpot (MIN) Range (% Base Speed)

0 – 30

0

Acceleration Trimpot (ACC) Range (Seconds)

0.2 – 10

1

Deceleration Trimpot (DEC) Range (Seconds)

0.2 – 10

1

Current Limit Trimpot (CL) Range (% Full Load)

0 – 200

150

IR Compensation Trimpot (IR) Range at 90/130 Volts DC Output (Volts DC)

0 – 10

5

IR Compensation Trimpot (IR) Range at 180/220 Volts DC Output (Volts DC)

0 – 20

10

Speed Regulation (50:1 Speed Range) (% Base Speed)

1

Speed Range (Ratio)

50:1

Operating Temperature Range (ºC)

0 – 45

Advertising
This manual is related to the following products: