Note: Disconnect main power when installing or changing the Plug-In
Horsepower Resistor®.

III. WIRING INSTRUCTIONS

Warning! Read Safety Warning, on page 5 before using this control.
Disconnect the AC line before wiring.

Note: To avoid erratic operation, do not bundle AC line and motor wires with wires
from signal following, Start/Stop Switch, Enable, or any other signal wires. Use
shielded cables on all signal wiring over 12” (30cm). Shield should be earth ground-
ed on the control side only. Wire the control in accordance with the National
Electrical Code requirements and other codes that may apply to your area. See
Figure 4 on page 13.

Be sure to properly fuse each conductor that is not at ground potential. Do not fuse
neutral or grounded conductors. See Section VIII, on page 18. A separate AC line
switch or contactor must be wired as a disconnect so that each ungrounded con-
ductor is opened. See Application Note, Section VII, on page 18.

TABLE 3 – PLUG-IN HORSEPOWER RESISTOR® SELECTION

Notes: 1) 1 HP = 0.75 kW. 2) The HP marking on the Plug-In Horsepower Resistor® does not apply to PWM controls.

!

!

Motor

Current

(Amps DC)

SCR Rated Motor

Horsepower Ranges (HP)

PWM Rated Motor

Horsepower Ranges (HP)

Plug-In

Horsepower Resistor®

CL Setting

(Amps DC)

90 Volt DC

180 Volt DC

130 Volt DC

200 Volt DC

Ω

Part No.

3.3 – 5.0

1/3 – 1/2

3/4 – 1

1/2 – 3/4

1 – 1

1

2

0.1

9838

7.5

2.5

1/4

1/2

1/3

3/4

0.18

9837

3.8

1.3 – 2.0

1/8 – 1/6

1/4 – 1/3

1/6 – 1/4

1/3 – 1/2

0.25

9836

3.0

0.7 – 1.0

1/15 – 1/10

1/6 – 1/5

1/12 – 1/8

1/6 – 1/4

0.51

9834

1.5

0.4 – 0.6

1/30 – 1/20

1/15 – 1/10 1/20 – 1/15

1/8 – 1/6

1

9833

0.9

0.1 – 0.3

1/100 – 1/50 1/50 – 1/25

1/50 – 1/30 1/25 – 1/20

2.0

9949

0.5