KB Electronics KBRG-212D User Manual

Page 15

Advertising
background image

15

TABLE 8 – FIELD CONNECTIONS (Shunt Wound Motors Only)

AC LINE

VOLTAGE

FIELD VOLTAGE

(VDC)

FIELD VOLTAGE

(VDC)

FIELD CONNECTION

115 90 100 F+,

F-

115 90 50 F+,

L1

230 180 200 F+,

F-

230 180 100 F+,

L1

230 *90 100 F+,

L1

*Step down operation. See Section 7.2, on page 20.



6.6

Full Voltage Field
Connection (Shunt
Wound Motors Only) –

Connect the motor field
leads to F+ and F-
terminals of TB3 as
shown in Figure 4, and
Table 7, on page 14.

Note: Do not connect

motor armature
leads to F+ and
F- terminals.

CAUTION! Do not use F+

and F- terminals of TB3 for
any purpose other than to
power the field of a shunt
wound motor.


6.7 Half Voltage Field

Connection (Shunt
Wound Motors Only) –

Connect the motor field
leads to F+, TB3 and L1
terminals of TB2, as
shown in Figure 5, and

Table 7, on page 14.


CAUTION! TB3 terminals are
not isolated from AC line. Do
not ground (earth).


Note: Do not connect

motor armature
leads to F+ and

F- terminals.

FIGURE 4 B FULL VOLTAGE FIELD CONNECTION

FIELD

F+ F-

-

+

M

AC LINE
INPUT

L1 L2 M2 M1

ARMATURE

FUSE

FU

SE

GND

(EARTH)

FU

SE

TB2

TB3

See Table 6, for Torque Requirements.

FIGURE 5 B HALF VOLTAGE FIELD CONNECTION

ARMATURE

L1 L2 M2 M1

AC LINE
INPUT

M

+

-

F+ F-

FIELD

FUSE

FUSE

GND

(EARTH)

TB2

TB3

See Table 6, for Torque Requirements.

Advertising