KB Electronics KBRG-212D User Manual

Page 18

Advertising
background image

18

FIGURE 7C - J17

VOLTAGE SCALE

FIGURE 7D - J8

CURRENT SCALE

10

0

15

J17

90V /

180 V

4

90V /

20mA

J17


6.10 Enable / Inhibit –
The control features an Enable / Inhibit function. The control can

be electronically stopped and started with the Enable / Inhibit circuit.


The Enable circuit functions opposite to that of the inhibit circuit. Inhibit: open to start,
close to stop. Enable: open to stop, close to start.


6.10.1
Enable Mode, EN (212D) – In the Enable mode (Default) connect COM

terminal to the EN terminal via a switch. See Figure 8A.

6.10.1 Inhibit Mode, INH (213D) – When COM terminal and EN terminal are open,

control is in “INHIBIT” state. See Figure 8B.

IMPORTANT

NOTE: In Enable mode a switch must be installed between the COM

and the EN terminals or control will not operate. See SAFETY WARNING, on page 5.

FIGURE 8A– ENABLE MODE

(CLOSE TO RUN)

FIGURE 8B – INHIBIT MODE

(CLOSE TO STOP)

COM EN

TB1

JUMPER J9

INH EN

SWITCH

JUMPER J9

JUMPER

COM EN

INH EN

TB1

Advertising