Table 1 – general specifications – KB Electronics Multi Speed Board User Manual

Page 5

Advertising
background image

Speed range selection jumpers (HI, LO) and Enable jumper (ENABLE) are also provided.
Other features include a barrier terminal block (TB1) to facilitate wiring and a connector
(CON2) to connect a tach-generator (TACH) for the KBMG.

STANDARD FEATURES

Multi-Speed Operation – Four (4) user Preset Speeds.

Forward and Reverse – Each preset provides a selection of forward and reverse direction.

Speed Range Settings – Each preset provides expanded trimpot adjustments for

motor speed range (0-100, 50-100, 0-50, 33-66 % base speed).

Enable – Provides electronic Run/Stop function.

PARAMETER

SPECIFICATION

Preset or Enable Switch Types

Dry Contact* or Open Collector

Maximum Operating Current per Preset (milliamps DC)

1.5

Operating Temperature Range (ºC)

0 – 50

*Note: Contacts must be isolated from the AC line.

TABLE 1 – GENERAL SPECIFICATIONS

FIGURE 2 – PRESETS 1 THRU 4

HI

LO

PRESET 1

HI

LO

LO

LO

HI

R/F

R/F

R/F

PRESET 2

PRESET 3

HI

PRESET 4

R/F

3

II.

SETTING SELECTABLE
JUMPERS (each preset)
The KBMG Multi-Speed Board has customer
selectable jumpers which can be set for a
specific application. See Figure 2.

Note: Disconnect the AC line before changing
position of jumpers.