Stop 20.00 hz, Programming the micro series, Micro series keypad functions – LEESON Micro Series Quick Reference Guide User Manual

Page 2: Micro series displays, Micro series keypad

Advertising
background image

STOP

20.00 HZ

PROG

RUN

AUTO

MAN

START

ENTER

FWD

REV

STOP

Press the START key to start the drive. The START key
is only active in LOCAL mode.

PROGRAMMING THE MICRO SERIES

1. Press the PROG/RUN key. This will cause the PASSWORD

prompt to appear (unless the password protection has been dis-
abled), as shown below:

PASSWORD

0000

CURSOR

2. Use the ARROW keys to scroll to the correct password value

(the factory default password is 0019) and press ENTER. The
PROGRAM mode will be entered at the start of the parameter
menu. A cursor will highlight the parameter name.

3. Use the ARROW keys to scroll to the desired parameter and

press ENTER. The cursor will shift from the parameter name
to the parameter value, as the example below illustrates:

ACCEL

30.0 SEC

CURSOR

ENTER

4. Use the ARROW keys to scroll to the desired parameter value,

and press ENTER to store the new value.

5. Press PROG/RUN to exit the PROGRAM mode.

START

MICRO SERIES KEYPAD FUNCTIONS

Press the STOP key to stop the drive.
NOTE: The STOP key is active in both LOCAL and
REMOTE mode.

The STOP key is also used to reset faults. If the fault
condition has passed, pressing the STOP key will clear
the fault and return the drive to a STOP condition.

STOP

UP and DOWN ARROWS — Used to change the speed
setpoint in MANUAL mode, scroll through the para-
meter menu, and change parameter values.

Toggles between AUTOMATIC (terminal strip) and
MANUAL (keypad) speed control.
NOTE: Parameter 28 — AUTO/MAN must be set to
BOTH for this key to be active.

AUTO

MAN

Toggles between forward and reverse directions.
ENTER key must pressed.

FWD

REV

Used to enter and exit the PROGRAM mode to set the
parameters.

PROG

RUN

ENTER

Used for: toggling the display between SPEED, LOAD,
and MOTOR VOLTAGE; confirming new parameter
values; confirming AUTO and MANUAL speed control
selections.

MICRO SERIES DISPLAYS

Shown below are examples of MICRO SERIES displays. To scroll
through the SPEED, LOAD, and MOTOR VOLTAGE displays,
press and release the ENTER key.

RUN

60.00

HZ

DRIVE

STATUS

SPEED

SETPOINT

SPEED

UNITS

RUN

85% LOAD

DRIVE

STATUS

PERCENT

LOAD

RUN

460 VAC

DRIVE

STATUS

MOTOR

VOLTAGE

MOTOR VOLTAGE

DISLAY

ENTER

ENTER

SPEED DISPLAY

LOAD DISPLAY

Press and hold the ENTER key to activate the AUXILIARY
MODE, which will toggle to a CONTROL DISPLAY. An example
is shown below:

ENTER

PRESS

& HOLD

LOCAL -- AUTO -- IDC

DRIVE

STATUS

MOTOR

VOLTAGE

SPEED

REFERENCE

SOURCE

AUXILIARY MODE

CONTROL DISPLAY

MICRO SERIES KEYPAD

ROTATION

DIRECTION

ROTATION

DIRECTION

ROTATION

DIRECTION

Advertising