175135.00REV1 / 175136.00REV1 HOOKUP DIAGRAMS

+

-

Battery

Caution:

Motor and battery wire must
be a minimum of 12 ga. and

a maximum of 6 ga.

White

Motor

Customer supplied

3PDT Center-off

Center-blocked switch

Relays may be used in place of switch, but a neutral position must be provided
to prevent plug reversing. Do not engage opposite direction until motor has
come to a complete stop. Failure to do so may result in damage to the control.

Pot High (P2-1)

Pot Wiper (P2-2)

Pot Low (P2-3)

Common (P2-4)

Inhibit (P2-5)

+Arm (P1-5)

+Battery (P1-4)

No Connect (P1-3)

-Arm (P1-2)

-Battery (P1-1)

5K

Speedpot

Orange

Red

Current Limit

Max Speed

Accel

I.R. Comp.

Min Speed

++

Optional

Inhibit

(see hook-up

below)

Customer

supplied

SPST switch

++

P1

P2

175135.00REV1 / 175136.00REV1 HOOKUP

+

-

+

-

Battery

Caution:

Motor and battery wire must
be a minimum of 12 ga. and

a maximum of 6 ga.

Pot High (P2-1)

Pot Wiper (P2-2)

Pot Low (P2-3)

Common (P2-4)

Inhibit (P2-5)

+Arm (P1-5)

+Battery (P1-4)

No Connect (P1-3)

-Arm (P1-2)

-Battery (P1-1)

5K

Speedpot

Orange

Red

White

Current Limit

Max Speed

Accel

I.R. Comp.

Min Speed

Motor

Optional

Inhibit

(see hook-up

below)

++

Customer supplied

SPST switch

++

P1

P2

175135.00REV1 / 175136.00REV1 REVERSING HOOKUP

Relays may be used in place of switch, but a neutral position must be provided to prevent plug reversing. DO NOT
ENGAGE OPPOSITE DIRECTION UNTIL MOTOR HAS COME TO A COMPLETE STOP. Failure to do so may
result in damage to the control.

Pot High (P2-1)

Pot Wiper (P2-2)

Pot Low (P2-3)

Common (P2-4)

Inhibit (P2-5)

5K

Speedpot

Orange

Red

White

SPST Switch

open = stop

close = run

P2

Pot High (P2-1)

Pot Wiper (P2-2)

Pot Low (P2-3)

Common (P2-4)

Inhibit (P2-5)

P2

SPST Switch

open = run

close = stop

Inhibit via speedpot - provides starting and

stopping through accel/decel parameters

Using inhibit input - provide fast start-

stop by bypassing accel/decel circuit

INHIBITING THE CONTROL - There are two methods that may be used to shut down the output without having
to break the battery supply (ie. inhibit the control).

4

CAUTION: DO NOT OPERATE CONTROL OUTSIDE THE
RECOMMENDED INPUT +/-10%