Fuse

Wire a power input fuse between the stop switch (if installed) and the BAT+ terminal on the circuit
board. The fuse should be rated at 150% of input voltage and 150 - 200% of maximum motor name-
plate current. An example of a fuse we recommend would be Cooper Bussmann AMG-125, AMG-150,
AMG-175, or AMG-200.

"!44%29

!

!

!

!

-/4/2

"!4

&USE

"!4

%MERGENCY
3TOP

Figure . Motor and Battery Connections