LevelOne FBR-1461 User Manual

Page 14

Advertising
background image

14

The detail instruction in Reset Button

Recovery procedures for non-working routers (e.g. after a failed firmware upgrade flash):

Hold the Reset Button on the back of the modem in. Keep this button held in and turn on the

modem. Once the lights on the modem have stopped flashing, release the Reset Button.

The modem's emergency-reflash web interface will then be accessible via

http://192.168.0.1

where you can upload a firmware image to restore the modem to a functional state. Please

note that the modem will only respond via its web interface at this address, and will not

respond to ping requests from your PC or to telnet connections.

Note:

Before powering on the router to enter the recovery process, please configure the IP

address of the PC as

192.168.0.100

and proceed with the following step by step guide.

1. Power the router off.

2. Hold the "Reset Button

”.

3. Power on the router. Then Router's IP will reset to Emergency IP address (Say

192.168.0.1)

4. Flash the firmware.