Figure 10-11 Alarm Config

The following entries are displayed on this screen:

Alarm Table

Select:

Select the desired entry for configuration.

Index:

Displays the index number of the entry.

Variable:

Select the alarm variables from the pull-down list.

Port:

Select the port on which the Alarm entry acts.

Sample Type:

Specify the sampling method for the selected variable and
comparing the value against the thresholds.

Absolute: Compares the values directly with the thresholds

at the end of the sampling interval.

Delta: Subtracts the last sampled value from the current

value. The difference in the values is compared to the
threshold.

Rising Threshold:

Enter the rising counter value that triggers the Rising Threshold
alarm.

Rising Event:

Select the index of the corresponding event which will be
triggered if the sampled value is larger than the Rising
Threshold.

Falling Threshold:

Enter the falling counter value that triggers the Falling Threshold
alarm.

Falling Event:

Select the index of the corresponding event which will be
triggered if the sampled value is lower than the Falling
Threshold.

Alarm Type:

Specify the type of the alarm.

All: The alarm event will be triggered either the sampled

value exceeds the Rising Threshold or is under the Falling
Threshold.

Rising: When the sampled value exceeds the Rising

Threshold, an alarm event is triggered.

Falling: When the sampled value is under the Falling

Threshold, an alarm event is triggered.