LevelOne GES-1651 User Manual

Page 52

Advertising
background image

46

PC A and Server A is in the same VLAN;

PC B and Server B is in the same VLAN;

PCs in the two VLANs cannot communicate with each other.

Network Diagram

Configuration Procedure

Configure Switch A

Step

Operation

Description

1

Configure

the

Link Type of the
ports

Required. On VLAN

→802.1Q VLAN→Port Config page, configure

the link type of Port 2, Port 3 and Port 4 as ACCESS, TRUNK and
ACCESS respectively

2

Create VLAN10

Required. On

VLAN→802.1Q VLAN→VLAN Config page, create a

VLAN with its VLAN ID as 10, owning Port 2 and Port 3.

3

Create VLAN20

Required. On

VLAN→802.1Q VLAN→VLAN Config page, create a

VLAN with its VLAN ID as 20, owning Port 3 and Port 4.

Configure Switch B

Step

Operation

Description

1

Configure

the

Link Type of the
ports

Required. On

VLAN→802.1Q VLAN→Port Config page, configure

the link type of Port 7, Port 6 and Port 8 as ACCESS, TRUNK and
ACCESS respectively.

2

Create VLAN10

Required. On

VLAN→802.1Q VLAN→VLAN Config page, create a

VLAN with its VLAN ID as 10, owning Port 6 and Port 8.

3

Create VLAN20

Required. On

VLAN→802.1Q VLAN→VLAN Config page, create a

VLAN with its VLAN ID as 20, owning Port 6 and Port 7.

Return to CONTENTS