Compatibility, Assumptions, The td series software – Teledyne LeCroy CANbus TD and CANbus TDM - Operators Manual User Manual
Page 6: Canbus trigger, decode, and measure

CANbus Trigger, Decode, and Measure
6
CANbus-TD-TDM-OM-E RevB
packages contain Search capability for specific IDs, Data and Errors and a Table displays
summarized protocol data underneath the oscilloscope grid.
Compatibility
The CANbus TDM option is compatible for WavePro Zi and WaveRunner Xi oscilloscopes. The
CANbus TD option is compatible with the WavePro Zi, WaveRunner Xi and WaveSurfer Xs
oscilloscopes. CAN triggering is completely integrated with the oscilloscope and no external
hardware is required. Earlier versions of LeCroy’s CANbus TDM and TD options required the use
of an external trigger module, for documentation ion how to use the external trigger module
please see the appendix. The external trigger module is still available for use with WaveMaster
8000A, WavePro 7000A, and WaveRunner 6000A oscilloscopes.
Note: All references to Decode and Measure/Graph capabilities and functionality are identical
whether the external or internal CAN trigger is being used.
Assumptions
This manual assumes a basic understanding of the FlexRay standard physical layer and protocol
layer specifications, and knowledge of how FlexRay is used. Also, a basic understanding of
oscilloscope operation - specifically the LeCroy oscilloscope which the FlexRay trigger, decode,
and physical layer option is used with - is assumed. Wherever practical or necessary, details on
specific oscilloscope features have been included in this manual.
Note: LeCroy has a policy of frequently updating software. While screen images in this manual
may not exactly match what is seen on your oscilloscope display, be assured that the
functionality is nearly identical.
The TD Series Software
The TD option adds the following capability to the LeCroy oscilloscope software user interface
dialogs:
1. Serial Trigger Selection - If this is the first serial trigger option you have installed on your
oscilloscope, an additional icon is shown on your trigger dialog box. It allows a serial
trigger condition to be set from within the oscilloscope using an easy-to-understand
interface.
2. Serial Decode - If this is the first serial decode option you have installed on your scope, an
additional set of Serial Decode and Decode Setup dialog boxes are provided for setup of