Electrical grounding instructions – Alto-Shaam 10.20ESG User Manual

Page 16

Advertising
background image

An electrical wiring diagram is located behind the control

panel on the left side of the oven. This appliance must be

branch circuit protected with proper ampacities, in

accordance with the wiring diagram located in the

electrical compartment of the oven.

Wire size for the main incoming power to the unit must

match the minimum size listed in the specifications

applicable to the specific oven model. For supply

connections, locate the wire size posted on the label

located on the electrical control box cover, behind the

service panel.

Before operating the oven, check all cable connections in

the electrical connection area for tightness since

connections can loosen during transport.

NOTE: After both water and elecrical connections have

been completed, operate the oven in any cooking

mode for a period of 15 minutes and recheck the

main power connections at the terminal block to

make certain they remain tight.

G A S C O M B I T H E R M

I N S T A L L A T I O N M A N U A L

#MN-28676

PG

. 14

®

C O M B I T HE R M

E L E C T R I C A L & I N S TA L L AT I O N R E Q U I R E M E N T S

AVERTISSEMENT: Directives pour la prise
de courant électrique Cet appareil est muni
d'une fiche à trios branches (prise de
Courant) afin de vous proéger des chocs et
doit être branché Directemet dans un
receptacle adequate de prise do courant À
trios branches. II ne faut pas couper ou
enlever une banche De cette fiche.

MODEL

VOLTAGE

PHASE CYCLE

/

HZ

AMPS

KW

CIRCUIT

AWG

6•10esG

110-120

1

50/60

5.7

.68

20 A

2

WIRE

PLUS GROUND

6•10esG/

SK

110-120

1

50/60

9.5

1.14

20 A

AWG

12

7•14esG

110-120

1

50/60

5.7

.68

20 A

2

WIRE

PLUS GROUND

7•14esG/

SK

110-120

1

50/60

9.5

1.14

20 A

AWG

12

10•10esG

110-120

1

50/60

5.7

.68

20 A

2

WIRE

PLUS GROUND

10•10esG/

SK

110-120

1

50/60

9.5

1.14

20 A

AWG

12

10•20esG

110-120

1

50/60

7.8

.936

20 A

2

WIRE

PLUS GROUND

AWG

12

12•18esG

110-120

1

50/60

7.8

.936

20 A

2

WIRE

PLUS GROUND

AWG

12

20•20esG

110-120

1

50/60

22.0

2.64

30 A

2

WIRE

PLUS GROUND

AWG

10

OTHER VOLTAGES AVAILABLE

: Range 200 — 415V, 1 or 3 ph, 50 or 60 Hz

380-415V:

To prevent an electrical shock hazard

between the appliance and other appliances

or metal parts in close vicinity, an

equalization-bonding stud is provided.

An equalization bonding lead must be

connected to this stud and the other

appliances / metal parts to provide

sufficient protection against potential

difference. The terminal is marked with

the following symbol.

D A N G E R

ELECTRICAL GROUNDING
INSTRUCTIONS:

This appliance is equipped with a
three-pronged (grounding) plug for
your protection against shock hazard
and should be plugged directly into a
properly grounded three-prong
receptacle. Do not cut or remove the
grounding prong from this plug.