Risk of electric shock – Alto-Shaam 10.20ESG User Manual

Page 17

Advertising
background image

G A S C O M B I T H E R M

I N S T A L L A T I O N M A N U A L

#MN-28676

PG

. 15

I N S TA L L AT I O N R E Q U I R E M E N T S

®

C O M B I T HE R M

The gas Combitherm must use a connector that
complies with The Standard for Connectors for
Movable Gas Appliances,

ANSI Z21.69 CSA 6.16

and addenda Z21.69a-1989. A quick disconnect
devise must be installed to comply with The
Standard for Quick Disconnect Devices for Use

with Gas Fuel,

ANSI Z21 CSA 6.9.

Adequate means must be provided to limit the
movement of this appliance. Limitation of
movement must be made without depending on
the connector, the quick disconnect device, nor the
associated piping designed to limit appliance
movement. If it becomes necessary to disconnect
the restraint, it must be reconnected immediately
following the return of the appliance to its
original position.

1.

Install a manual gas shut-off valve along with an
approved disconnect device.

2.

Install an A.G.A. certified, heavy-duty connector
that complies with ANSI Z 21.69 or CAN 1-6.10m88
along with a quick-disconnect device in compliance
with ANSI Z21.41 or CAN 1-6.9m70. Connectors
must be installed with a cable restraint to prevent
excessive tension from being placed on the
connector.

M O B I L E E Q U I P M E N T R E S T R A I N T

D R I P T R AY I N S TA L L AT I O N

The appliance is shipped without the drip tray
installed. This must be installed before equipment
operation begins.

Position drip tray mounting bracket beneath oven.

Secure with lock washer and phillips screws supplied.

Slide drip tray assembly into mounting bracket.

Secure with lock washer and nut.

Attach drip tray hose to drip tray assembly. Secure the

drain fitting connection with the 19mm clamp. Secure

the drip tray hose connection with the 20mm clamp.

ITEM

NO

.

PART

NO

.

PART DESCRIPTION

QTY

1

1006674

DRIP TRAY MOUNTING BRACKET

1

2

DRIP TRAY

1

3

HO-27220 DRIP TRAY HOSE

1

W A R N I N G

FAILURE TO PROPERLY INSTALL THE

DRIP TRAY CAN OR WILL CAUSE

MAJOR EQUIPMENT DAMAGE AND

WILL RESULT IN A LEAKAGE

HAZARD THAT CAN CAUSE

PERSONAL INJURY.

W A R N I N G

RISK OF ELECTRIC SHOCK.

Appliance must be secured

to building structure.

Advertising