7. Install leads to Rocker Switch




2.10.4 INSPECTION OF WIRING



VISUAL INSPECTION

• While disconnecting the connectors, never pull the Wiring Harnesses. Unlock the

connector first and then pull them apart by holding Connectors themselves.

• While connecting Connectors, also hold Connectors and put them together until they lock

securely (a click is heard).

• While Installing the Wiring Harness, fix it with clamps so that no slack is left.

• While using a tester for checking continuity or measuring voltage, be sure to insert the

tester probe from the Wire harness side.