IEI Integration KINO-945GSE2 User Manual

Page 102

Advertising
background image

KINO-945GSE2 Motherboard

Page 90

Auto Fan by Duty

Cycle

Manual Mode by

RPM

The fan spins at the speed set in:

Fan

PWM

control

Manual Mode by

Duty Cycle

CPU Temp. Limit of Highest [050]

WARNING:

CPU failure can result if this value is set too high

The fan will turn off if the temperature falls below this value.

Minimum Value: 0°C

Maximum Value: 127°C

Temp. Limit of Start [020]

WARNING:

CPU failure can result if this value is set too high

When the fan is off, it will only start when the temperature exceeds this setting.

Minimum Value: 0°C

Maximum Value: 127°C

Start PWM [070]

This is the initial speed of the fan when it first starts spinning.

PWM Minimum Mode: 0

PWM Maximum Mode: 127

Advertising