5.4.1 Flat Panel Configuration
Use the Flat Panel Configuration menu (BIOS Menu 6) to set the configuration settings
for the flat panel screen connected to the system.
BIOS Menu 6: Flat Panel Configuration
Flat Panel Type [Auto]
Use the Flat Panel Type option to specify the type of flat panel screen connected to the
system.
TFT
Specifies the system is connected to a TFT display.
LVDS
Specifies the system is connected to an LVDS display.
Auto
(Default) The system detects the display type and the display
settings.
Resolution [800 x 600]
The Resolution option can only be configured if the Flat Panel Type option is not set to
Auto. Use the Resolution option to set the resolution of the flat panel screen connected
to the system. The Resolution options are: