Serial Port2 Address [2F8]

Use the Serial Port2 Address option to select the Serial Port 2 base address.

Disabled

No base address is assigned to Serial Port 2

2F8 D

EFAULT

Serial Port 2 I/O port address is 3F8 and the interrupt

address is IRQ3

3E8 Serial Port 2 I/O port address is 3E8 and the interrupt

address is IRQ4

2E8 Serial Port 2 I/O port address is 2E8 and the interrupt

address is IRQ3

Serial Port2 IRQ [4]

Use the Serial Port2 IRQ option to select the interrupt address for serial port 2.

3

Serial port 2 IRQ address is 3

4 D

EFAULT

Serial port 2 IRQ address is 4

10

Serial port 2 IRQ address is 10

11

Serial port 2 IRQ address is 11

Serial Port3 Address [3E8]

Use the Serial Port3 Address option to select the base addresses for serial port 3

Disabled

No base address is assigned to serial port 3

3E8 D

EFAULT

Serial port 3 I/O port address is 3E8

2E8

Serial port 3 I/O port address is 2E8

2E0

Serial port 3 I/O port address is 2E0

Serial Port3 IRQ [3]

Use the Serial Port3 IRQ option to select the interrupt address for serial port 3.