5 3-pin power terminal block, Figure 3-11: rj-45 ethernet connector, Figure 3-12: 3-pin terminal block pinout location – IEI Integration TANK-101B-D525_N455 v1.00 User Manual

Page 34: Table 3-4: rj-45 ethernet connector leds

Advertising
background image

TANK-101B/BW Em b e d d e d S ys te m

P a g e 24

Figure 3-11: RJ-45 Ethernet Connector

The RJ-45 Ethernet connector has two status LEDs, one green and one yellow. The green

LED indicates activity on the port and the yellow LED indicates the port is linked. See

Table 3-4.

Activity/Link LED

Speed LED

STATUS

DESCRIPTION

STATUS

DESCRIPTION

Off

No link

Off

10 Mbps connection

Yellow

Linked

Green

100 Mbps connection

Blinking

TX/RX activity

Orange

1 Gbps connection

Table 3-4: RJ-45 Ethernet Connector LEDs

3.7.5 3-p in P o we r Te rm in a l Blo c k

CN Typ e :

3-pin terminal block

CN Lo c a tio n :

See Figure 1-3

N P in o u ts :

See Figure 3-12

Connect the leads of a 9V~36V DC power supply into the terminal block. Make sure that

the power and ground wires are attached to the correct sockets of the connector.

Figure 3-12: 3-pin Terminal Block Pinout Location