Installation – Lincoln Electric P709 GUARDIAN CONTROL SOLUTIONS User Manual
Page 14

A-7
INSTALLATION
GUARDIAN CONTROL™ SOLUTIONS
A-7
PHYSICAL DIMENSIONS AND PROPERTIES
TECHNICAL SPECIFICATIONS - SLIDING VALVES
FIRE SUPPRESSION
MATERIAL HOUSING
Galvanized Steel
AMBIENT CONDITIONS
OPERATING TEMPERATURE:
MINIMUM
NOMINAL
MAXIMUM
-4ºF (-20ºC)
68ºF (+20ºC)
122ºF (+50ºC)
OUTDOOR USE ALLOWED
Yes (if housed in a weather-tight enclosure and com-
pressed air is not allowed to cool down below its dew
point)
SHIPPING DATA
GROSS WEIGHT
See Table A.1
PACKING DIMENSIONS
See Table A.1
HARMONIZED TARIFF CODE
8481.3091.90
COUNTRY OF ORIGIN
Germany
TECHNICAL DATA
PNEUMATIC CYLINDER
PRESSURE:
NORMAL
MAXIMUM
58-73 psi (4-5 bar)
131 psi (9 bar)
COMPRESSED AIR QUALITY
Dry and oil-free according to ISO 8573-3 class 6
SOLENOID VALVE
TYPE OF VALVE
5/2 solenoid valve with spring reset
ACTING TYPE
NC (normally closed)
POWER SUPPLY
24 VAC
POWER CONSUMPTION
3 W
ELECTRICAL CONNECTION
According to DIN 43650
POWER TOLERANCE
+/- 10%
POWER REQUIREMENT
Approx. 5 W
PROTECTION CLASS
IP 65
INSULATION CLASS
B
COMPRESSED AIR CONNECTION
Quick release for ø 0.24 in. (6 mm) hose