Installation, Warning – Lincoln Electric P709 GUARDIAN CONTROL SOLUTIONS User Manual
Page 23

A-16
INSTALLATION
GUARDIAN CONTROL™ SOLUTIONS
A-16
Spark Guardian™ 10/16/20 Components (See
Figure A.4)
• Spark Guardian™, consisting of inlet(A), Cyclone(B)
and outlet(D), connected by duct clamp(C)
• Dustbin 13 liters(F)
• Dustbin 27 liters(F)
• Dustbin cover incl. connection flange and hose(E)
For duct connection of Spark Guardian™: (See
Figure A.8)
• Reducer (2) from metric Ø 250/400/500 mm. to impe-
rial Ø 10/16/20 in.(A)
• Duct clamp (2) Ø 200/400/500 mm(B)
For connection of vertical duct Ø 8 in. between
Spark Guardian™ and dustbin: (See Figure A.10)
• Reducer (2) from metric Ø 200 in. to imperial Ø 8
in.(A)
• Duct clamp Ø 200 mm(B)
If parts are missing or damaged, contact your supplier.
MOUNTING
Spark Guardian™
The Spark Guardian™ can be mounted:
• During installation of new ductwork.
• Afterwards in an existing duct.
• Allow sufficient space between the duct and the wall
to install the Spark Guardian™.
To mount the Spark Guardian™, proceed as follows.
1. Observe the mounting instructions as indicated in
Figure A.5 and Figure A.6.
2. In case of installation in an existing duct: cut away a
piece of the existing duct. See Figure A.7 on (D) for
duct length to be removed.
Lifting the Spark Guardian™ in an
incorrect manner can cause injury of
death.
The Spark Guardian™ can be mount-
ed as a whole. Lift it using (e.g.):
• Sling
• Forklift-truck with pallet
When no lifting gear is available, it is recommend-
ed to mount the inlet and outlet separately and to
reconnect them afterwards.
-----------------------------------------------------------------------
WARNING
FIGURE A.5 – AIRFLOW DIRECTION
Airflow direction
FIGURE A.6 – PERPENDICULAR WITHOUT
BENDS
Perpendicular without bend(s)