Enable limits – Lincoln Electric IM10180 POWER FEED 25M NNS User Manual

Page 45

Advertising
background image

B-30

OPERATION

POWER FEED™ 25M NNS

If the passcode does not equal zero (0000), enter the
passcode now. If the passcode has been forgotten, a
p.c. computer application is required to change the
passcode.

If the passcode has been set to zero (0000), SETUP will
illuminate on the user interface and the display will show
the following:

Four items show on the user interface.

• Memory Value
• High Limit
• Low Limit
• Parameter Name

One of these items will flash to indicate which item will
change when the user interface encoder is rotated.
Press the right button on the user interface to select the
item to change.

The Limits Setup menu shows a list of all parameters
available for the weld mode stored in the memory cho-
sen. For example, if limits are being set for a stick
(SMAW) mode, parameters such as Run-in WFS and
Postflow will not appear.

To lock a parameter to a specific value that cannot
be changed, set the high and low limits to the
same value.

WELD WFS

HI = 200 LOW = 180

200

START OPTIONS

END OPTIONS

SET

SETUP

WELD MODE

RC CONTROL

WELD WFS

HI = 200 LOW = 180

200

START OPTIONS

END OPTIONS

SET

SETUP

WELD MODE

ARC CONTROL

Memory Value

Parameter Name

Low Limit

High Limit

The memory value must always be less than or equal
to the high limit, and greater than or equal to the low
limit.

After setting limits, press the memory button with the
flashing LED. The display will ask to save or discard
the limit changes just made. Press the left user inter-
face for button (YES) to save and enable the limits
and exit. Press the right button (NO) to exit and leave
limits unchanged.

Enabling/Disabling Limits

Limits for each memory may be enabled or disabled
by pressing and hold the appropriate memory button
for 10 seconds. Release the memory button when the
display shows the following:

If the passcode does not equal zero, enter the passcode
now. If the passcode is zero (0000), SETUP will light
and the displays the following:

Press the left button (YES) to enable limits or the right
button (NO) to disable limits. Disabling limits does not
change any limits values that may have been previ-
ously set.

A

GUN

B

1

5

2

6

3

7

4

8

M

M

Enable/Disable

Limits: Press

10 seconds

Rotate to

Change

Value.

Press to

select item

to change.

MEMORY 2 LIMITS
ENABLE/DISABLE

WELD MODE

ARC CONTROL

START OPTIONS

END OPTIONS

Yes

No

WELD MODE

ARC CONTROL

ENABLE LIMITS?

START OPTIONS

END OPTIONS

SET

SETUP