TROUBLE SHOOTING

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

PROBLEMS

(SYMPTOMS)

RECOMMENDED

COURSE OF ACTION

POWER FEED™ 25M NNS

POSSIBLE

CAUSE

Fault Code

Err 006

Err 100

Err 53 Voltage sense loss.

Err 81 Motor overload, long term.

Err 82 Motor overload, short term.

Err 263 No usable weld modes.

Description

1. The wire feeder has not received

a recognition command from the
power source.

1. The power source has issued a

shutdown command.

1. The wire drive motor has over-

heated.

1. The wire drive motor current draw

has exceeded limits, usually
because the motor is in a locked
rotor state.

1. The power source does not have

any welding programs loaded.

Possible Adjustments

1. Verify the power source is operat-

ing properly. (Status light steady
green.)

2. Check control cable for loose or

broken leads.

3. See power source Instruction

Manual.

1. Verify the power source is operat-

ing properly (Status light steady
green.)

2. Check control cable for loose or

broken leads.

3. See power source Instruction

Manual.

1. Check that the electrode slides

easily through the gun and cable.

2. Remove tight bends from the gun

and cable.

3. Check that the spindle brake is

not too tight.

4. Verify a high quality electrode is

being used.

5. Wait for the error to reset and the

motor to cool. (approximately 1
minute).

1. Check that motor can turn freely

when idle arm is open.

2. Verify that the gears are free of

debris and dirt.

1. See the power source Instruction

Manual for load welding pro-
grams.

Linc-Net System Error Codes

ArcLink System Error Codes