Caution – Lincoln Electric IM10180 POWER FEED 25M NNS User Manual

Page 54

Advertising
background image

E-4

TROUBLE SHOOTING

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

PROBLEMS

(SYMPTOMS)

POWER FEED™ 25M NNS

CAUTION

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Variable or "hunting" arc.

Poor arc starts with sticking or
"blast-offs", weld porosity, narrow
and ropy looking bead.

The wire feed speed/amperage and
voltage/trim display work during pre-
set but show nothing during welding.

1. Wrong size, worn and/or melted

contact tip.

2. Worn work cable or poor work

connection.

3. Wrong polarity.

4. The gas nozzle is extended

beyond the contact tip or the wire
stickout is too long.

5. Poor gas shielding on processes

requiring gas.

1. Improper procedures or tech-

niques.

1. The software in the POWER

FEED™ 25M NNS must be
upgraded.

1. Replace the contact tip.

2. Verify all work and electrode con-

nections are tight and that the
cables are in good condition.
Clean/replace as necessary.

3. Adjust polarity to the recommend-

ed procedure.

4. Adjust the gas nozzle and shorten

the stickout to 3/8 to 1/2 inches.

5. Check gas flow and mixture.

Remove or block sources of
drafts.

1. See "Gas Metal Arc Welding

Guide". (GS-100).

1. Contact the local authorized

Lincoln Field Service Shop.

Output Problems

Advertising