Installation, Technical specifications – Lincoln Electric IM10022 POWER WAVE AC_DC 1000 SD User Manual

Page 10

Advertising
background image

A-1

INSTALLATION

POWER WAVE

®

AC/DC 1000

®

SD

A-1

TECHNICAL SPECIFICATIONS -

Power Wave

®

AC/DC 1000

®

SD (K2803-1)

OUTPUT

RECOMMENDED INPUT WIRE AND FUSE SIZES

1

PHYSICAL DIMENSIONS

TEMPERATURE RANGES

INPUT AT RATED OUTPUT - THREE PHASE ONLY

INPUT VOLTS

3 PHASE

50/60 Hz

380
400
460
500
575

OPEN

CIRCUIT

VOLTAGE

70V

70VACpk.

3 PHASE INPUT

VOLTAGE 50/60Hz

380
400
460
500
575

HEIGHT

49.13 in

1248 mm

CONFORMITY MARK

MODEL

K2803-1

WIDTH

19.71 in

501mm

DEPTH

46.60 in

1184 mm

WEIGHT

800 lbs.

363 kg.

TIME-DELAY FUSE

OR BREAKER

2

AMPS

100

90
90
80
70

COPPER GROUNDING

CONDUCTOR

AWG (mm

2

)

8 (10)
8 (10)
8 (10)
8 (10)
10 (6)

TYPE 90°C

COPPER WIRE

3

IN

CONDUIT

AWG (mm

2

)

3(25)
3(25)
4(25)
4(25)
6(16)

PROCESS CURRENT RANGES (AC or DC)

SAW-DC+

100 amps @24 Volts

SAW-DC-

1000 Amps @44 Volts

SAW-AC

(Actual range may be limited by process)

AUXILIARY POWER

(CIRCUIT BREAKER

PROTECTED)

40 VDC AT

10 AMPS

115 VAC AT

10 AMPS

INPUT

CURRENT AMPS

82
79

69
62

55

IDLE

POWER

WATTS

225

POWER FACTOR

@ RATED OUTPUT

.95

EFFICIENCY

@ RATED OUTPUT

86%

OUTPUT

CONDITIONS

1000A@44V.

100% Duty Cycle

OPERATING TEMPERATURE RANGE

14°F to 104°F(-10°C to 40°C)

STORAGE TEMPERATURE RANGE

-40°F to 185°F(-40°C to 85°C)

1 Wire and Fuse Sizes based upon the U.S. National Electric Code and maximum output for 40°C (104°) ambient.
2 Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers that have a delay in tripping action that decreases as the

magnitude of current increases.

3 Fail to use proper type of copper wire will cause fire hazards.
* An external filter will be required to meet CE and C-Tick conducted emission requirements. It will meet CE and C-Tick requirements with the

use of an optional external filter. (K2444-3 CE and C-Tick Filter Kit)

}

WELDING PROCESSES

Process

SAW

Electrode Diameter Range

5/64 – 7/32" (2 – 5.6 mm)

Output Range (Amperes)

100 - 1000

Wire Feed Speed Range

See Wire Drive Manual

Insulation Class: Class F(155°C)

EN 60974-1
CSA C/US

*

Advertising