Installation, Input and ground connections, A-4 input fuse and supply wire considerations – Lincoln Electric IM10022 POWER WAVE AC_DC 1000 SD User Manual

Page 13: Input voltage selection, Input connection, Warning, Voltage=500v

Advertising
background image

POWER WAVE

®

AC/DC 1000

®

SD

INPUT AND GROUND CONNECTIONS

MACHINE GROUNDING

The frame of the welder must be grounded. A ground
terminal marked with the symbol shown is located
inside the reconnect / input access door for this
purpose. See your local and national electrical codes
for proper grounding methods.

A-4

INSTALLATION

A-4

INPUT FUSE AND SUPPLY WIRE
CONSIDERATIONS

Refer to Specifications page for recommended fuse and
wire sizes. Fuse the input circuit with the recommended
super lag fuse or delay type breakers (also called "inverse
time" or "thermal/magnetic" circuit breakers). Choose input
and grounding wire size according to local or national
electrical codes. Using fuses or circuit breakers smaller than
recommended may result in "nuisance" shut-offs from
welder inrush currents, even if the machine is not being
used at high currents.

INPUT VOLTAGE SELECTION

Welders are shipped connected for the highest input voltage
listed on the rating plate. To move this connection to a
different input voltage, see the diagram located on the inside
of the input access door, or the diagram shown below
(Figure A.2). If the Auxiliary lead (indicated as ʻAʼ) is placed
in the wrong position, there are two possible results.

a. If the lead is placed in a position higher than the applied

line voltage, the welder may not come on at all.

b. If the Auxiliary lead is placed in a position lower than the

applied line voltage, the welder may not come on, and
fuse in the reconnect area may open. If this occurs, turn
off the input voltage, properly connect the auxiliary
lead, replace the fuse, and try again.

INPUT CONNECTION

ELECTRIC SHOCK can kill.

• Only a qualified electrician should

connect the input leads to the
Power Wave

®

. Connections

should be made in accordance
with all local and National
Electrical Codes and the
connection diagram located on
the inside of the reconnect / input
access door of the machine.
Failure to do so may result in
bodily injury or death.

-----------------------------------------------------------------------

Use a three-phase supply line. A 1.75 inch (45 mm)
diameter access hole for the input supply is located on
the case back. Connect L1, L2, L3 and ground
according to the Input Supply Connection Diagram.

FIGURE A.2 - INPUT SUPPLY CONNECTION FOR K2803-1 POWER WAVE

®

AC/DC 1000

®

SD

S26

0

4

7

TH

E L

IN

C

O

LN ELEC

T

RIC

C

O

. CL

E

VEL

AN

D

,

OHIO

U

.S.

A

.

VOLTAGE=440-460V

'A'

A

500V

U / L1

V / L2

CR1

W / L3

INPUT SUPPLY CONNECTION DIAGRAM

550-575V

ELECTRIC

SHOCK

CAN KILL

WARNING

Do not operate with covers removed

Disconnect input power before servicing

Do not touch electrically live parts

Only qualified persons should install,
use or service this equipment

440-460V

VOLTAGE=500V

'A'

500V

550-575V

440-460V

VOLTAGE=550-575V

'A'

500V

550-575V

440-460V

VOLTAGE=380-415V

'A'

500V

550-575V

440-460V

380-415V

380-415V

380-415V

380-415V

WARNING

Advertising