B-4

OPERATION

B-4

TCV400

1. 24-PIN CONNECTOR RECEPTACLE

FIGURE B.1

PIN

LEAD NO.

FUNCTION

1

32

115 VAC

2

---

---

3

31A

115 VAC

4

---

---

5

GND

Chassis Connection

6

24

24 VAC

7

41B

24 VAC

8

225B

Voltage Feedback

9

77

Output Control

10

76

Output Control

11

75

Output Control

12

215B

Voltage Feedback

13

---

---

14

---

---

15

32B

Power Supply Enabled (115 VAC)

16

---

---

17

---

---

18

41A

Power Supply Enabled (24 VAC)

19

474A

24 VDC

20

474A

24 VDC

21

476A

24 VDC

22

476A

24 VDC

23

216A

Current Feedback, 100mV=750A

24

215A

Current Feedback, 100mV=750A

23

22

21

20

19

18

17

16

15

14

13

11

10

9

8

7

6

5

4

3

2

1

24

12

WELDING CONTROLS

(See Figure B.2)

AUXILIARY POWER CONNECTIONS

The power source is equipped to furnish nominally
115 volt AC, 24 volt AC and 24 volt DC auxiliary
power for operating wire feeding equipment, etc. The
auxiliary power is available at the 24-pin connector
receptacle on the control panel and/or at a terminal
strip behind the hinged control panel on the front of
the power source.

2. 115V AC

is available at receptacle pins 1 and 3,

terminals 31 and 32. A 10A circuit breaker protects
this circuit.

3. 24V AC

is available only at receptacle pins 6 and

7. A 5A circuit breaker protects this circuit.

4. 24V DC

is available only at receptacle pins 19,

20, 21 and 22. A 15A circuit breaker protects this
circuit.

The 115V AC and the 24V AC are isolated circuits.

5. POWER SUPPLY LIGHT

A red light on the machine control panel indicates
when the tigger is enabled. This means auxiliary
power is being used.

6. THERMAL PROTECTION LIGHT

An amber light on the machine control panel indi-
cates when either of the two protective thermostats
have opened. Output power will be removed but
input power will still be applied to the machine.

7. PILOT LIGHT

A white light on the machine control panel indicates
when the power source input contactor is closed.
This means the main power transformer and all
auxiliary and control transformers are energized.

8. 115 VOLT POWER SWITCH

The power input contactor operates from an auxil-
iary 115 volt transformer that is energized through
the POWER toggle switch on the machine control
panel. “ I ” is on and “0” is off.

9. OUTPUT CONNECTIONS

The output terminals are recessed on the case
front. The TCV400 provides Tweco connector
receptacles.

Connect the positive output lead to the terminal
marked “+”. The negative output lead can be
hooked to either the low inductance terminal
(marked “ ” ) or the high inductance termi-
nal ( marked “ ”).

POLARITY SELECTION

Polarity selection is made by appropriately connect-
ing the electrode and work welding cables to either
the “

+

” stud or to one of the “

-

” studs.