Installation, Technical specifications – tcv400 – Lincoln Electric IM10063 TCV400 User Manual

Page 9

Advertising
background image

A-1

INSTALLATION

TCV400

A-1

TECHNICAL SPECIFICATIONS – TCV400

Idle Current - Amps

3.2A (380V 50 Hz)

MAX OCV: 46

Input kVA

29.6 @ 400A 34V (50 Hz)

Power Factor

.65 @ 400A 34V (50 Hz)

Rated Current

45A @ 400A 34V (380V/50 Hz)

Efficiency

70% @ 400A 34V (50 Hz)

Idle Power

1.0 KW (50 Hz)

MISC. INFORMATION

RATED INPUTS

RATED OUTPUTS

Height

Width

Depth

Weight

27.5 in.

23.28 in.

32.0 in.

383 lbs

699 mm

591 mm

813 mm

(174 kg)

PHYSICAL DIMENSIONS

Duty Cycle

50%

60%

100%

Standard Voltage

50/60 Hz

200/230/400/460

Volts

39V

Amps

500A

450A

400A

Operating Temperature -40°C to +40°C

Output Range

60A 17V (Minimum)

500A 39V (Maximum)

RECOMMENDED INPUT WIRE AND FUSE SIZES

INPUT

VOLTAGE /

FREQUENCY

200
230
400
460

TYPE 75°C

(SUPER LAG)

OR BREAKER

SIZE (AMPS)

1

125 Amp
125 Amp

70 Amp
60 Amp

TYPE 75°C

GROUND WIRE

IN CONDUIT

AWG(IEC-MM

2

) SIZES

6 (14)
6 (14)

8 (8.4)

10 (5.3)

TYPE 75°C

COPPER WIRE

IN CONDUIT

*

AWG(IEC-MM

2

) SIZES

30°C (86°F) Ambient

3 (27)
4 (21)

8 (8.4)
8 (8.4)

INPUT AMPERE

RATING ON

NAMEPLATE

**

78
75
43
39

HERTZ

50/60

* Ambient temperature of 40°C (104°F).
** At rated output of 400A, 100% duty cycle.

Advertising