Machine has low output and no con-
trol.

Machine does not have maximum
output.

Machine will not shut off.

Erratic Current.

1. Open in feedback circuitry.

2. Faulty Control PC Board.

1. One input fuse blown.

2. One phase of main transformer

open.

3. Faulty Control PC Board.

1. Input contactor contacts frozen.
2. Defective Power “I/O

switch, (S1).

1. Poor work or electrode connec-

tion.

2. Welding leads too small.

3. Welding current or voltage too

low.

4. Defective main SCR bridge.

1. Check wiring and control PC

Board wiring harness plugs.

2. Replace. See Procedure for

Replacing PC Boards.

1. Check and replace if blown after

checking for reason for blown
fuse.

2. Check for open and repair.

3. Replace. See Procedure for

Replacing PC Boards.

1. Check and replace if necessary.
2. Replace.

1. Check and clean all connections.

2. Check table in instruction manual.

3. Check procedures for recom-

mended settings.

4. Check and replace if defective.