The gear box is located within the

feed body on the same side as the

roll release handle. It has a non-

lubricated gear box so it is essentially

maintenance free.

The Rapid-Air servo was run and fully

tested before being shipped from our

plant. Carefully inspect all parts when

uncrating them. If you find any dam-

aged parts, please report it to the car-

rier that delivered the servo drive and

at the same time, report the damage to

your distributor.

The servo feed container should

contain:

1) servo feed – standard

1) console – standard

insTAllATion, roll PressUre & releAse, PiloT releAse

Installation

1) console stand – optional

1) servo mounting bracket – optional

1) cascade roller assembly – optional

Please contact someone at your

facility to verify what options you

purchased.

If a mounting bracket was purchased,

then it should be mounted first

being careful that the center line of the

bracket lines up with the centerline of

the die area. The servo can then be

mounted on the bracket. A print of the

bracket can be found in the back of

this manual.

If a bracket was not purchased,

then the servo will have to be mounted

on the press bed or customer

provided bracket. Line up the rolls

to be centered and perpendicular

to the center line of the die area.

Included in the back of this manual

is a hole pattern layout print for the

MSA2 servo.

The roll pressure knob is located on the

entrance side of the feed and is a knurl-

ed knob with a locking nut located

right behind it. It is positioned parallel

to the inlet face and uses a compres-

sion spring for adjusting roll pressure.

Roll.Pressure

The roll release handle is located on the side of the feed. Lifting the handle

opens the rolls and lifting to its stop will lock the rolls in place. This is a true

statement if the pilot release stop is not set. If the stop is set, then the roll will

only raise until the stop is reached just like in automatic for pilot release.

Roll.Release.Handle

The optional electric pilot release can be mounted on the entrance side of the

servo at the place labeled “inlet.” It is the customer’s responsibility to interface

the pilot release valve with the customer supplied, press-mounted, activating

switch. The air requirements for the release to work correctly is 80 to 120 psi,

dry filtered and lightly lubricated air. There should be a minimum of 2 CFM

available at all times.